Eave & Soffit EmberVents™

$9.85

Description

Critical Defense for Horizontal Applications

Our eaves and soffit vents are designed to provide robust ember protection for these highly vulnerable areas of your home. While our vents are fire-rated for extreme ember attacks, it’s important to note that mesh-only vents may not be permitted for horizontal applications in some Wildland-Urban Interface (WUI) zones. Always consult your local jurisdiction’s latest building codes to ensure compliance with specific material requirements for these installations. With FireStorm Building Products, you can count on high-quality solutions tailored to enhance your home’s wildfire defense at an affordable price.

NFVA & Cut Out

Select a product to see dimensions.

Specifications

Aperture: 0.0657”
Wire Diameter: 0.018”
Finish: Black Powder Coat
Stainless Steel Grade: 304

wildland urban interface badge

WUI & IWUI Compliant

astm e-84 class a rated icon

Class-A Rating

astm e-2768 ignition resistant rated icon

Ignition Resistance Rated

astm e-2886 ember flame diffuse listed icon

Tested for Ember and Flame* Impingement

STOPS the embers from entering.

TRAPS embers within the mesh aperture.

REFLECTS the radiant heat from fires.

Specifications, Certification, and Testing Standards

FireStorm® EmberVents™ and EmberMesh™ are rigorously tested and certified to meet the highest standards for fire resistance and safety. These products have been evaluated to ASTM E2886, ASTM E84, and ASTM E2768 testing standards, ensuring their durability and effectiveness in wildfire defense. Additionally, our vents are compliant with IBHS's "Wildfire Prepared Home" program and approved for use under California’s Chapter 7A building code, as well as other state IWUI requirements. With FireStorm, you can trust that your home is protected by solutions that exceed industry standards for performance and reliability.

While FireStorm® EmberVents™ and EmberMesh™ are approved for vertical installations under California’s Chapter 7A building code, certain horizontal applications may require materials beyond mesh-only solutions. Please consult your local building codes and regulations to ensure compliance with all installation requirements.

Check out the FireStorm® EmberVent™ product specs and download the Spec Sheet to find everything you need to know.

Download Spec Sheet

FireStorm™ EmberMesh™ Specs

Steel Grade
304 Stainless Steel
Wildfire defense that lasts, corrosion and ignition resistant.
Finish
Black Thermal Powder Coated
Additional layer of corrosion resistant thermal layer, low visibility index for a seamless look.
Aperture
0.0657"
The perfect balance of breathability and ember protection.
Wire Diameter
0.018"
Sturdy wire to keep insects and critters out!
Ignition Resistant
ASTM E2768

Standard Test Method for Extended Duration Surface Burning Characteristics of Building Materials [QAI Listing # B1155]

Class A Rated
ASTM E84

Surface Burning Characteristics of Building Materials

[QAI Listing # B1155]

Ember and Flame Resistance
ASTM E2886

Evaluating the Ability of Exterior Vents to Resist the Entry of Embers and Direct Flames Impingement [QAI Listing # B1155]

Flame Impingement
ASTM E2912 *(vertical test)

Fire Test on Non-Mechanical Dampers Used in Vented Construction [QAI Listing # B1155] *Not recommended for flame defense

Flame and Ember Resistant Vent
Chapter 7A, 706A2

FireStorm® EmberMesh™ and EmberVents™ meet the requirements of the California Building Code, Chapter 7A - 706A2 when installed in a vertical orientation.*

Off Ridge and Ridge Vents
Chapter 7A, 706A2.1

FireStorm® EmberMesh™ and EmberVents™ meet the requirements of the California Building Code, Chapter 7A - 706A2.1

Ignition Resistant Building Material

Minimum standards for the location, design, and construction of buildings and structures based on fire hazard severity in the wildland-urban interface.

FireStorm® EmberMesh™ and EmberVents™ meets or exceeds the following 2024 IWUIC.

FireStorm™ Ember Vents IWUI

Class 1
504.10.1 Performance when installed in a vertical orientation.*
504.10.2 Prescriptive
Class 2
505.10.1 Performance when installed in a vertical orientation.*
505.10.2 Prescriptive
Class 3
506.5 Vents

Quality Materials

FireStorm® EmberVents™ are made out of 304 Stainless Steel making it the best choice for those who want a durable material.

Built to Resist Wildfires

Firestorm® EmberVents™ are designed for defense! They are resistant to flames, embers, and corrosion, and are able to withstand exposure to the elements without degrading or breaking down.

98% Ember Blockage

Firestorm® EmberVents™ are designed with a small aperture to keep embers out, including debris.
The small aperture size prevents embers from passing through the mesh, which is a major concern for those who live in W.U.I areas.

EmberVents™ Installation

1. Remove the Existing Vent

If the existing vent obstructs the installation of the new vent screen, carefully remove it. If the vent is recessed and does not interfere, you can leave it in place.

2. Measure the Rough Opening

Measure the dimensions of the rough opening where the new vent will be installed. Ensure accurate measurements to select the correct size vent. Choose one of our vents that is big enough to ensure that our mounting flange sufficiently over laps your building material and allows you to securely fasten our vent to your building, leaving no gaps for possible ember penetration.

3. Prepare the Vent

If you have chosen one of our available colors, you can skip this section and begin mounting your vent. If you’ve chosen our Bonderized finish option, you can paint your vent directly without the need for primer. Masking off the vent face is optional. Our black powder coating nearly disappears once the vents are installed. Select the appropriate fasteners based on the type of siding on your home. This could include screws, nails, or other fasteners suitable for your siding material.

4. Mount the Vent

Position the new vent over the rough opening and secure it using your selected fasteners. We recommend fastener spacing of 6”. Ensure the vent is firmly attached and properly aligned with the siding. For uneven surfaces, more fasteners may be needed. If you find screwing directly through the metal frame difficult, you can pre-drill guide holes at each corner of the metal frame with a metal drill bit. This will make screwing the fasteners much easier.

ember mesh installed over foundation vent opening with drill on mock home

5. Checking Your Installation

Ensure that your vent is securely fastened to your siding and that there are no gaps bigger than 1/16” that could allow for ember intrusion.

6. Vent Assemblies

For installation instruction on our full vent assemblies, such as dormer vents, gables vents, and 2-way vents, consult your local building professional.

Vulnerable Areas to Use EmberVents™

Let’s Build a Safer Future!

Give us a call or submit your information via the form and a team member will get back to you.

phone icon

Phone

(916) 652-7424

clock icon

Hours

Mon. - Fri. 8AM - 4PM Pacific Time

email icon

Email

info@firestormbuildingproducts.com

Please enter a number from 00000 to 99999.
If you are requesting an order, please list the product type, size, and quantity needed.
Newsletter Signup

Description

Critical Defense for Horizontal Applications

Our eaves and soffit vents are designed to provide robust ember protection for these highly vulnerable areas of your home. While our vents are fire-rated for extreme ember attacks, it’s important to note that mesh-only vents may not be permitted for horizontal applications in some Wildland-Urban Interface (WUI) zones. Always consult your local jurisdiction’s latest building codes to ensure compliance with specific material requirements for these installations. With FireStorm Building Products, you can count on high-quality solutions tailored to enhance your home’s wildfire defense at an affordable price.

Additional information

Vent Size

3.5" x 14", 5.5" x 14", 7.5" x 14", 3.5" x 22", 5.5" x 22", 7.5" x 22"

Flange Type

Standard, Tabbed