Louvered Vents

Protection From the Elements

Louvered vents provide protection from the elements like wind-driven rain, snow and even critters. Commonly used in exterior wall applications, like gable-end walls for attic applications, or low on a home (such as foundation and crawlspace applications) to support proper airflow. In the summer, the home may be cooled with air conditioning but heat rises, getting caught under the roof—so high wall venting helps release trapped heat and stabilize attic temperatures. The same can be said of the winter; extreme temperature shifts are even harder on an attic’s open space. In lower-wall applications, airflow helps manage foundation and crawlspace moisture by reducing damp, stale air that can contribute to musty odors and conditions that support mold and mildew.

Assembled in the USA

Providing necessary attic ventilation,
but self-closing when it matters most.

Our fire and ember-resistant continuous vents for soffits provide the needed ventilation into attic space down the entire length of the soffit. 

V2 Vents are ideal for new construction in various materials and retrofit kits are available for existing continuous vents on the home. Strip vents such as ours do not use airflow-interrupting baffles, resulting in more venting per square inch. Our continuous vents for soffits feature a stainless steel ember screen and intumescent matrix that closes in the event of high heat. 

 

fire Resistant Continuous Vents - Providing necessary attic ventilation but self-closing when it matters most
EverKem Fire Stop 814

Use EverKem Fire Caulking

  1. We recommend using EverKem 814+, intumescent fire caulking with all installation of V2 Vents.
    • Our round eave vents are the exception: EverKem 136, mortar based caulking should be used when mounting hardware isn’t an option and flanges are minimal.
  2. INSTALLATION: Prior to installing the vent, run a bead of EverKem behind the nailing flange to ensure an air tight seal where the vent meets the building material. This ensures that no gaps are present between the vent and your building material where flying embers might enter!

For ordering information, contact us.

Vulnerable Areas

Depending on your home’s design, the attic and crawlspaces of a home are some of the most vulnerable areas of a home during a wildfire attack, and if those spaces are ventilated, they must be protected. The Vulcan Vent is equipped with a stainless steel ember-stopping mesh and an intumescent honeycomb layer that expands to block heat and flames —helping to protect these vulnerable openings while still allowing the ventilation of your attic, foundation, or crawlspace to aspirate properly.

gable vent with stainless steel ember-catching mesh screen
closeup photo of fire-resistant vent honeycomb

Home safety starts with fire-resistant venting.

Due to an ember-catching mesh screen and an intumescent coating that expands in high heat, the V2 Vent is prepared to protect a house from dangerous embers and flames. The fire and ember-stopping technology are positioned behind the louvers, making for a safe and attractive louvered vent. 

V2 Vents can be easily installed in a variety of construction material including:

  • Wood Siding
  • Stucco
  • Mil Core
  • Foam Back
  • Fiber Cement

V2 Vent Ember-Resistant Vents Include:

  • G90 hot dipped, galvanize steel (unless customized)
  • 304 stainless steel ember mesh
  • Honeycomb matrix with 1 hour intumescent coating
  • Galvanized pest abatement screen (some models excluded)

Louvered Applications: Flange Styles

These installation examples showcase various flange styles and how they can be used to layer into a louvered end application. We offer various flange styles for new and existing construction. Because our louvered vents are extremely durable and storm resistant, they also make a great choice when used as a foundation / crawlspace vent!

Flange Front Louvered Vent

Stucco Louvered Vent

Foam Back Louvered Vent

Fiber Cement Louvered Vent

Retrofit Applications

Pick the right flange for the job!

Not all flange styles are ideal for retrofit applications. This is due to certain flange styles being designed to go behind your building’s exterior cladding. If your shingles or stucco is existing for instance, it would be difficult to get the nail flange behind that material. If removing the existing vent is possible, a trusty “Flange Front”, or FF style is often used.

Retrofitting, or “home hardening” are terms often used when upgrading, or replacing an existing vent with a fire and ember resistant vent. There are many methods used to accomplish that goal.  We offer louvered vents with a “retrofit flange”, designed to be installed over the face of an existing louvered vent. [not shown]  However, there are other options to consider.

We offer our V2 Matrix as a standalone product. This is our most flexible option. Installation is simple; simply cut to fit and then, install from the back side of the existing vent. This method can be used to retrofit louvereds, dormers, and even foundation vents. You can find the instructions here.

Need a little help? Head over to our Installers page to see our rapidly growing list of trusted contractors that can tackle the job for you!

V2 Vent
Features

Fire Resistant Retrofits kit - Honeycomb matrix closing technology - built into galvanized steel frame

Honeycomb matrix closing technology with ember-catching screen mesh built into galvanized steel frame

Fire Resistant Retrofits kit - Baffle-free design for maximum airflow (NFVA) to keep your home dry

Open louver design for high airflow (NFVA). Protection from wind-driven rain and snow with a classic look.

Fire Resistant Retrofits kit - Designed to meet the new California Building code State Fire Marshal

Designed to meet the new California Building code State Fire Marshal (OSFM) 12 Chapter 7A of the California Wildland-Urban Interface (WUI) fire code program

Fire Resistant Retrofits kit - Passed the American Society for Testing and Materials (ASTM) E2886

Passed the American Society for Testing and Materials (ASTM) E2886 to effectively block ember entry

It’s time for your home to protect itself.

 * For coastal environments, copper, stainless or powder coated finishes are highly recommended. *

Flange Styles

Standard Finishes

G90 Galvanized, Stainless, Copper, Bonderized

Mfg. Part # Description NFVA(square inches) Flange Style Cut Out(inches) Spec. Sheet(download) Sample Image
FSVG1412FB 14" x 12" FOAM BACK FLANGE recessed 1-1/2" 58 Foam Back 14 X 12 download icon view icon
FSVG1412FC 14" x 12" FIBER CEMENT FLANGE recessed 3/8" 58 Fiber Cement 14 X 12 download icon view icon
FSVG1412FF 14" x 12" FLANGE FRONT 58 Flange Front 14 X 12 download icon view icon
FSVG1412FM 14" x 12" FLANGE MIDDLE recessed 1-5/16" 58 Recessed 14 X 12 download icon view icon
FSVG1412R 14" x 12" RETROFIT FLANGE recessed 2-5/8" 58 Retrofit 14 X 12 download icon view icon
FSVG1412S 14" x 12" FLANGE SET BACK 3/4" STUCCO 58 Stucco 14 X 12 download icon view icon
FSVG1418FB 14" x 18" FOAM BACK FLANGE recessed 1-1/2" 86 Foam Back 14 X 17.5 download icon view icon
FSVG1418FC 14" x 18" FIBER CEMENT FLANGE recessed 3/8" 86 Fiber Cement 14 X 17.5 download icon view icon
FSVG1418FF 14" x 18" FLANGE FRONT 86 Flange Front 14 X 17.5 download icon view icon
FSVG1418FM 14" x 18" FLANGE MIDDLE recessed 1-5/16" 86 Recessed 14 X 17.5 download icon view icon
FSVG1418R 14" x 18" RETROFIT FLANGE recessed 2-5/8" 86 Retrofit 14 X 17.5 download icon view icon
FSVG1418S 14" x 18" FLANGE SET BACK 3/4" STUCCO 86 Stucco 14 X 17.5 download icon view icon
FSVG1424FB 14" x 24" FOAM BACK FLANGE recessed 1-1/2" 115 Foam Back 14 X 23.5 download icon view icon
FSVG1424FC 14" x 24" FIBER CEMENT FLANGE recessed 3/8" 115 Fiber Cement 14 X 23.5 download icon view icon
FSVG1424FF 14" x 24" FLANGE FRONT 115 Standard 14 X 23.5 download icon view icon
FSVG1424FM 14" x 24" FLANGE MIDDLE recessed 1-5/16" 115 Recessed 14 X 23.5 download icon view icon
FSVG1424R 14" x 24" RETROFIT FLANGE recessed 2-5/8" 115 Retrofit 14 X 23.5 download icon view icon
FSVG1424S 14" x 24" FLANGE SET BACK 3/4" STUCCO 115 Stucco 14 X 23.5 download icon view icon
FSVG148FB 14" x 8" FOAM BACK FLANGE recessed 1-1/2" 29 Foam Back 14 X 7.5 download icon view icon
FSVG148FC 14" x 8" FIBER CEMENT FLANGE recessed 3/8" 29 Fiber Cement 14 X 7.5 download icon view icon
FSVG148FF 14" x 8" FLANGE FRONT 29 Flange Front 14 X 7.5 download icon view icon
FSVG148FM 14" x 8" FLANGE MIDDLE recessed 1-5/16" 29 Recessed 14 X 7.5 download icon view icon
FSVG148R 14" x 8" RETROFIT FLANGE recessed 2-5/8" 29 Retrofit 14 X 7.5 download icon view icon
FSVG148S 14" x 8" FLANGE SET BACK 3/4" STUCCO 29 Stucco 14 X 7.5 download icon view icon
FSVM1424 14" x 24" NFVA DEPENDANT ON OPENINGS Dependant Retrofit, V2 Matrix N/A download icon view icon
FSVM2424 24" x 24" NFVA DEPENDANT ON OPENINGS Dependant Retrofit, V2 Matrix N/A download icon view icon
FSVM4824 48" x 24" NFVA DEPENDANT ON OPENINGS Dependant Retrofit, V2 Matrix N/A download icon view icon

Our Gallery

Happy Clients
Testimonials