Eave Vents

The overhang that cools the attic is also the one embers reach first.

Eave vents feed outside air into the attic space beneath the roof. That circulation matters most in the evening, when heat stored in the attic insulation all day needs somewhere to go — moving it out quickly is what keeps cooling costs down.

The eave — the underside of the roof that overhangs the exterior wall — usually sits directly above landscaping, shrubs, and other combustible material. That overhang, paired with an open vent, is exactly where wind-blown embers tend to collect during a wildfire.

wildland urban interface badge
astm e-84 class a rated icon
astm e-2768 ignition resistant rated icon
astm e-2886 ember flame diffuse listed icon
V2-baffle-free-design

Roofline Protection

Built to Resist Ignition at the Roofline

V2 Vents’ eave vents are noncombustible and corrosion-resistant, with an ember-catching wire mesh screen and an intumescent coating that self-closes at high temperature when wildfire is nearby.

Skipping airflow-restricting baffles also means more net free area per square inch of vent.

Quality Manufacturing

What’s Built Into Every V2 Vent

V2 Matrix Intumescent Technology

Reacts at critical temperatures to defense against heat and flames

Exceptional Airflow

Our Net-Free-Vent-Area (NFVA) specifications are verified by accredited 3rd parties for airflow performance you can trust!

Code-Aware Design

Built to align with Wildland Urban Interface code in California’s Chapter 5 (Chapter 7A) -> CWUI and beyond -> IWUI etc.

Independently Tested

Evaluated to ASTM E2886 and ASTM2912 for resistance to ember entry and direct flame impingement in both, horizontal and vertical directions.

Open Rafter Eave Vent Diagrams

V2-FSVE-install

Forward Tabbed Eave Vent

V2-FSVER-install

Round Eave Vent

V2-FSVE-RT-install

Reverse Tabbed Eave Vent

* These diagrams are conceptual, not installation instructions — consult a licensed building professional for project-specific guidance.

Critical Step

Sealing the Install with EverKem

  • Use EverKem 814+ intumescent fire caulking on every V2 Vents installation. Round eave vents use EverKem 136 mortar-based caulking instead, where mounting hardware isn’t practical and flanges run minimal.
  • Installation: Run a bead of EverKem behind the nailing flange before setting the vent — this keeps the seam between vent and building material airtight, closing off any gap embers could use to get in.
Contact Us For Ordering

Close Off the Eave’s Biggest Weak Point

Have a question about V2 Vents, wildfire-resistant construction, retrofit work, custom sizes, or a code-aware project? Get in touch and take the next step towards wildfire safety today.

wildfire mitigation contractor pointing at eave underside vents

Flange Types & Kits

Protection built for both framing types.

V2 Vents makes ember-resistant venting for both truss and rafter framing:

  • Tabbed (winged) eave vents for trusses and rafters
  • Reverse-tabbed eave vents for new construction
  • Round eave vents (bird-hole style), mini-louvered version
  • Round eave vents (bird-hole style), mesh-face version

Available for new construction and as retrofit kits over existing openings.

eave-honeycomb-mesh-graphic

Eave V2 Vents Spec Table

Give the Eave a Vent That Closes When It Counts

* Within 5 miles of the coast, copper, stainless steel, or a powder-coated finish holds up better than standard galvanized against salt air. *

Eave V2 Vents

Filter by Flange Style
MFG. PART # DESCRIPTION Flange Style NFVA (sq. in.) Cut Out (in.) SPEC SHEET
FSVE3514 3.5" x 14" TABBED EAVE VENT Standard 24 2x4 Rafters - 16" OC PDF
FSVE3514RT 3.5" x 14" REVERSE TAB EAVE VENT Reverse Tab 24 2x4 Rafters - 16" OC PDF
FSVE3522 3.5" x 22" TABBED EAVE VENT Standard 41 2x4 Rafters - 24" OC PDF
FSVE3522RT 3.5" x 22" REVERSE TAB EAVE VENT Reverse Tab 41 2x4 Rafters - 24" OC PDF
FSVE5514 5.5" x 14" TABBED EAVE VENT Standard 44 2x6 Rafters - 16" OC PDF
FSVE5514RT 5.5" x 14" REVERSE TAB EAVE VENT Reverse Tab 44 2x6 Rafters - 16" OC PDF
FSVE5522 5.5" x 22" TABBED EAVE VENT Standard 75 2x6 Rafters - 24" OC PDF
FSVE5522RT 5.5" x 22" REVERSE TAB EAVE VENT Reverse Tab 75 2x6 Rafters - 24" OC PDF
FSVE7514 7.5" x 14" TABBED EAVE VENT Standard 75 2x8 Rafters - 16" OC PDF
FSVE7514RT 7.5" x 14" REVERSE TAB EAVE VENT Reverse Tab 75 2x8 Rafters - 16" OC PDF
FSVE7522 7.5" x 22" TABBED EAVE VENT Standard 119 2x8 Rafters - 24" OC PDF
FSVE7522RT 7.5" x 22" REVERSE TAB EAVE VENT Reverse Tab 119 2x8 Rafters - 24" OC PDF
FSVER1 1" ROUND LOUVERED FACE FIRE VENT Flange Front 1 1 Round Hole PDF
FSVER1M 1" ROUND MESH FACE FIRE VENT Flange Front 1 1 Round Hole PDF
FSVER15 1.5" ROUND LOUVERED FACE FIRE VENT Flange Front 1.5 1.5 Round Hole PDF
FSVER15M 1.5" ROUND MESH FACE FIRE VENT Flange Front 1.5 1.5 Round Hole PDF
FSVER2 2" ROUND LOUVERED FACE FIRE VENT Flange Front 1 2 Round Hole PDF
FSVER2M 2" ROUND MESH FACE FIRE VENT Flange Front 2 2 Round Hole PDF
FSVER3 3" ROUND LOUVERED FACE FIRE VENT Flange Front 2 3 Round Hole PDF
FSVER3M 3" ROUND MESH FACE FIRE VENT Flange Front 4 3 Round Hole PDF
FSVER4 4" ROUND LOUVERED FACE FIRE VENT Flange Front 4 4 Round Hole PDF
FSVER4M 4" ROUND MESH FACE FIRE VENT Flange Front 8 4 Round Hole PDF

Let’s Build a Safer Future!

Give us a call or submit your information via the form and a team member will get back to you.

phone icon

Phone

(916) 652-7424

clock icon

Hours

Mon. – Fri. 8AM – 4PM Pacific Time

email icon

Email

info@firestormbp.com

Early Product Launch Announcement!

We are making FireStorm Building Products available to the public early due to the overwhelming demand!

You can access our products in one of two ways:

California Residents

Please enter your zip code to find a store near you!

Non-California Residents

Please contact us for a free quote!

Contact Us