Dormer Vents
Raised, exposed, and worth protecting.
A dormer vent’s job is releasing built-up attic heat — but because it sits proud of the roofline rather than flush against it, it’s also an easier target for wind-blown embers. Fitting the opening with a V2 Vent keeps the heat-release function while closing off that ember pathway.
Product Lineup
The V2 Vents Dormer Lineup Covers
- Low-profile ‘eyebrow’ vents
- Usable as an off-ridge vent on sloped roofing, or as an intake/exhaust vent on a flat roof
- Half-round dormer vents (’round’ vents)
- Pair with horizontal vents where cross-ventilation is needed
- Retrofit kits for existing dormer openings
Each model carries its own NFVA (net free ventilation area) rating — the square-inch measure of open ventilation a vent provides.
Critical Step
Sealing the Install with EverKem
- Use EverKem 814+ intumescent fire caulking on every V2 Vents installation. Round eave vents use EverKem 136 mortar-based caulking instead, where mounting hardware isn’t practical and flanges run minimal.
- Installation: Run a bead of EverKem behind the nailing flange before setting the vent — this keeps the seam between vent and building material airtight, closing off any gap embers could use to get in.
Upgrade Your Home’s Weakest Vent Openings
Have a question about V2 Vents, wildfire-resistant construction, retrofit work, custom sizes, or a code-aware project? Get in touch and take the next step towards wildfire safety today.
The vent openings decide how the home responds to fire.
V2 Vents’ dormer vents are built on corrosion-resistant G90 galvanized steel, with an ember-catching mesh screen backed by an intumescent coating that expands and seals the opening when fire gets close.
Quality Manufacturing
What’s Built Into Every V2 Vent
V2 Matrix Intumescent Technology
Reacts at critical temperatures to defense against heat and flames
Exceptional Airflow
Our Net-Free-Vent-Area (NFVA) specifications are verified by accredited 3rd parties for airflow performance you can trust!
Code-Aware Design
Built to align with Wildland Urban Interface code in California’s Chapter 5 (Chapter 7A) -> CWUI and beyond -> IWUI etc.
Independently Tested
Evaluated to ASTM E2886 and ASTM2912 for resistance to ember entry and direct flame impingement in both, horizontal and vertical directions.
Dormer V2 Vents Spec Table
Give your roofline a vent that does more than vent.
* Within 5 miles of the coast, copper, stainless steel, or a powder-coated finish holds up better than standard galvanized against salt air. *
Dormer V2 Vent
Sub Base V2 Vent Spec Table
Sub Base Details
Let’s Build a Safer Future!
Give us a call or submit your information via the form and a team member will get back to you.