Soffit Vents

Ventilation from underneath, protection built in.

Soffit vents sit on the underside of a roof eave, and sometimes under arches, balconies, decking, beams, cornices, or vaults. They pull cooler air in at the base of the roof while hot, humid attic air escapes higher up through roof vents — circulation that keeps moisture from condensing into mold and mildew.

wildland urban interface badge
astm e-84 class a rated icon
astm e-2768 ignition resistant rated icon
astm e-2886 ember flame diffuse listed icon

Code Compliant Ventilation

Built for the Job the Soffit Actually Faces

Ventilation you don’t have to think about — until it matters.

California’s Chapter 7A / CWUIC Chapter 5 Wildland-Urban Interface code requires ember- and fire-resistant vents on homes in WUI zones. V2 Vents soffit vents meet that bar with a noncombustible, corrosion-resistant body: an inner wire mesh screen stops embers on contact, and an intumescent coating expands under heat to close off the opening.

Available for stucco, wood, foam-and-stucco, fiber cement, and retrofit installations.

Critical Step

Sealing the Install with EverKem

  • Use EverKem 814+ intumescent fire caulking on every V2 Vents installation. Round eave vents use EverKem 136 mortar-based caulking instead, where mounting hardware isn’t practical and flanges run minimal.
  • Installation: Run a bead of EverKem behind the nailing flange before setting the vent — this keeps the seam between vent and building material airtight, closing off any gap embers could use to get in.
Contact Us For Ordering

Standard Soffit Flange Diagrams

V2-FSVE-FSVFS-FB-install

Foam Back Soffit Vent

V2-FSVE-FSVFS-FC-install

Fiber Cement Soffit Vent

V2-FSVE-FSVFS-FF-install

Flange Front Soffit Vent

V2-FSVE-FSVFS-S-install

Stucco Soffit Vent

* These diagrams are conceptual, not installation instructions — consult a licensed building professional for project-specific guidance.

Ventilation That Knows When to Close

Have a question about V2 Vents, wildfire-resistant construction, retrofit work, custom sizes, or a code-aware project? Get in touch and take the next step towards wildfire safety today.

Code Compliant Ventilation

Protecting the Openings Embers Look For First

Ventilation you don’t have to think about — until it matters.

Every vent opening on exterior walls, under roofing, and at the foundation is a potential ember entry point during wildfire — wind carries embers well ahead of the fire front, and an unprotected vent gives them a direct line to combustible material inside. V2 Vents stay open for everyday airflow but close down fast when an ember-catching screen and self-sealing coating are called on to do their job.

Improved Ventilation

No Baffles, More Airflow Per Square Inch

Skipping the airflow-restricting baffle found in some designs lets air circulate more freely under the roof covering, so each vent delivers more net free area per square inch.

v2-soffit-vents-group

Quality Manufacturing

What’s Built Into Every V2 Vent

V2 Matrix Intumescent Technology

Reacts at critical temperatures to defense against heat and flames

Exceptional Airflow

Our Net-Free-Vent-Area (NFVA) specifications are verified by accredited 3rd parties for airflow performance you can trust!

Code-Aware Design

Built to align with Wildland Urban Interface code in California’s Chapter 5 (Chapter 7A) -> CWUI and beyond -> IWUI etc.

Independently Tested

Evaluated to ASTM E2886 and ASTM2912 for resistance to ember entry and direct flame impingement in both, horizontal and vertical directions.

Foundation V2 Vents Spec Table

Protect the Part of the Home You Don’t See

* Within 5 miles of the coast, copper, stainless steel, or a powder-coated finish holds up better than standard galvanized against salt air. *

Foundation-Soffit V2 Vent

Filter by Flange Style
MFG. PART # DESCRIPTION Flange Style NFVA (sq. in.) Cut Out (in.) SPEC SHEET
FSVFS1824AV 18" x 24" FOUNDATION ACCESS VENT Flange Front 177 17.5 x 23.5 PDF
FSVFS414FB 4" x 14" FOAM BACK FLANGE SET BACK 1-1/2" Foam Back 24 3.5 X 13.5 PDF
FSVFS414FC 4" x 14" FIBER CEMENT FLANGE SET BACK 3/8" Fiber Cement 24 3.5 X 13.5 PDF
FSVFS414FF 4" x 14" FLANGE FRONT Flange Front 24 3.5 X 13.5 PDF
FSVFS414S 4" x 14" STUCCO SET BACK 3/4" Stucco 24 3.5 X 13.5 PDF
FSVFS614FB 6" x 14" FOAM BACK FLANGE SET BACK 1-1/2" Foam Back 41 5.5 X 13.5 PDF
FSVFS614FC 6" x 14" FIBER CEMENT FLANGE SET BACK 3/8" Fiber Cement 41 5.5 X 13.5 PDF
FSVFS614LFF 6" x 14" FLANGE FRONT Flange Front 20 6 X 14 PDF
FSVFS614FF 6" x 14" FLANGE FRONT Flange Front 41 5.5 X 13.5 PDF
FSVFS614S 6" x 14" STUCCO SET BACK 3/4" Stucco 41 5.5 X 13.5 PDF
FSVFS814FB 8" x 14" FOAM BACK FLANGE SET BACK 1-1/2" Foam Back 62 7.5 X 13.5 PDF
FSVFS814FC 8" x 14" FIBER CEMENT FLANGE SET BACK 3/8" Fiber Cement 62 7.5 X 13.5 PDF
FSVFS814FF 8" x 14" FLANGE FRONT Flange Front 62 7.5 X 13.5 PDF
FSVFS814LFF 8" x 14" FLANGE FRONT Flange Front 31 8 X 14 PDF
FSVFS814S 8" x 14" STUCCO SET BACK 3/4" Stucco 62 7.5 X 13.5 PDF

Let’s Build a Safer Future!

Give us a call or submit your information via the form and a team member will get back to you.

phone icon

Phone

(916) 652-7424

clock icon

Hours

Mon. – Fri. 8AM – 4PM Pacific Time

email icon

Email

info@firestormbp.com

Early Product Launch Announcement!

We are making FireStorm Building Products available to the public early due to the overwhelming demand!

You can access our products in one of two ways:

California Residents

Please enter your zip code to find a store near you!

Non-California Residents

Please contact us for a free quote!

Contact Us