Removable venting that satisfies California’s balcony inspection law.

SB 721 and SB 326 exist because too many ‘exterior elevated elements’ — balconies, decks, walkways — were failing without warning; state audits found structural problems in roughly 1 in 5 of the structures reviewed. Both bills, together with the California Building Code, now require an inspection vent on balconies and similar elements, giving inspectors a direct way to check structural members without cutting into the assembly. V2 Vents’ balcony inspection vents meet that requirement and are evaluated to California Building Code Chapter 7A / CWUIC Chapter 5 and ASTM E2886, with Cal Fire approval for use in Wildland-Urban Interface (WUI) zones.

wildland urban interface badge
astm e-84 class a rated icon
astm e-2768 ignition resistant rated icon
astm e-2886 ember flame diffuse listed icon

Built to Code, Start to Finish

  • Sized to SB 326 and SB 721 requirements
  • Chapter 7A / CWUIC Chapter 5, WUI compliant
  • Tested and listed to ASTM E2886 (flame and ember intrusion)
  • CAL Fire approved

Available in 4” width X 2’, 3’, 4’, 5′, 6’, 7′, 8′, 9′, 10’ lengths.

balcony-inspection-vents-twins

Installing the Vent

Built for horizontal installation under decks, balconies, walkways, stairways, and soffits.

Because materials and framing vary so widely between buildings, this page provides a general installation guide covering the key specification points — model-specific spec sheets are in the table below.

View Installation PDF

Access for Inspectors. Protection for Everyone Else.

Have a question about V2 Vents, wildfire-resistant construction, retrofit work, custom sizes, or a code-aware project? Get in touch and take the next step towards wildfire safety today.

balcony-inspection-vents-twins

Critical Step

Sealing the Install with EverKem

  • Use EverKem 814+ intumescent fire caulking on every V2 Vents installation. Round eave vents use EverKem 136 mortar-based caulking instead, where mounting hardware isn’t practical and flanges run minimal.
  • Installation: Run a bead of EverKem behind the nailing flange before setting the vent — this keeps the seam between vent and building material airtight, closing off any gap embers could use to get in.
Contact Us For Ordering

Let’s Build a Safer Future!

Give us a call or submit your information via the form and a team member will get back to you.

phone icon

Phone

(916) 652-7424

clock icon

Hours

Mon. – Fri. 8AM – 4PM Pacific Time

email icon

Email

info@firestormbp.com

Why SB 721 and SB 326 Exist

SB 326

SB 326 applies to condominiums and other common-interest developments, requiring regular inspection of exterior elevated elements after a series of balcony collapses exposed how easily structural problems could go undetected. The bill requires inspection vents specifically so inspectors can evaluate the core structural components directly, rather than relying on a visual check of the exterior alone — a more proactive standard for keeping these buildings safe over time.

SB 721 covers multifamily rental buildings more broadly, following the same pattern: a series of exterior-elevated-element failures prompted a regular-inspection requirement, and inspection vents are the mechanism that makes those inspections actually possible without invasive, destructive access. The goal for property owners and managers is the same — catch structural problems before they become safety incidents.

SB 721

The Cost of Skipping the Vent

Inspecting a balcony without a dedicated access vent usually means cutting into the structure to see anything at all — destructive, expensive, and still incomplete, since it’s easy to miss a problem area outside the cut. An inspection vent gives an inspector a real, repeatable way to check the same structural points over time, catching rot or weakened supports early enough to repair rather than replace. It’s a small, one-time installation cost against the alternative: a structural problem that goes unnoticed until it becomes a safety incident.

walkway-inspection

Foundation V2 Vents Spec Table

Protect the Part of the Home You Don’t See

* Within 5 miles of the coast, copper, stainless steel, or a powder-coated finish holds up better than standard galvanized against salt air. *

Balcony Inspection V2 Vent

MFG. PART # DESCRIPTION NFVA (sq. in.) Cut Out (in.) SPEC SHEET
FSVSC424IF 4" X 24" INSPECTION VENT - BALCONY & DECK 39 4.25" x 24.125" PDF
FSVSC436IF 4" X 36" INSPECTION VENT - BALCONY & DECK 58 4.25" x 36.125" PDF
FSVSC448IF 4" X 48" INSPECTION VENT - BALCONY & DECK 77 4.25" x 48.125" PDF
FSVSC460IF 4" X 60" INSPECTION VENT - BALCONY & DECK 96 4.25" x 60.125" PDF
FSVSC472IF 4" X 72" INSPECTION VENT - BALCONY & DECK 115 4.25" x 72.125" PDF
FSVSC484IF 4" X 84" INSPECTION VENT - BALCONY & DECK 135 4.25" x 84.125" PDF
FSVSC496IF 4" X 96" INSPECTION VENT - BALCONY & DECK 153 4.25" x 96.125" PDF
FSVSC4108IF 4" X 108" INSPECTION VENT - BALCONY & DECK 172 4.25" x 108.125" PDF
FSVSC4120IF 4" X 120" INSPECTION VENT - BALCONY & DECK 192 4.25" x 120.125" PDF

Frequently Asked Questions About V2 Balcony Inspection Vents

Why is there a vent on my balcony?

It’s a Balcony Inspection Vent, required under the California Building Code and under SB 721 / SB 326. It gives inspectors a direct way to check the structural condition of the balcony without cutting into it.

Are these vents suitable for multi-family buildings?

Yes — they’re built for exactly that use case, covering both new construction and retrofit installs on existing multifamily buildings.

Do these vents work with stucco and other exterior wall materials?

Yes. They install cleanly into stucco and other common exterior wall materials, whether it’s new construction or a retrofit, without disrupting the building’s appearance.

Do these vents satisfy the California Senate Bill requirements?

Yes — V2 Vents balcony inspection vents are built to meet the standards set out in SB 721 and SB 326 for exterior elevated element inspection and maintenance.

Can these be sized to fit a specific balcony?

Yes. They’re available in 4 in width across a range of lengths (see Sizing above), so most balcony configurations — new construction or retrofit — have a fit.

Do these vents affect balcony ventilation and airflow?

No — if anything they help it. Proper airflow through the vent reduces moisture buildup that can otherwise lead to dry rot, mold, and structural damage over time.

Can property owners reuse these vents for future inspections?

Yes — that’s the point of a removable design. Inspectors get repeatable access without damaging the balcony soffit or surrounding components each time.

Who should actually perform the inspection?

A licensed architect or structural engineer — someone qualified to assess structural integrity and confirm compliance with the applicable building code.

Do these vents meet ASTM standards for ember resistance?

Yes — they’re tested to ASTM E2886, which supports fire safety in high-risk wildfire (WUI) areas in addition to the SB 721 / SB 326 inspection requirement.