Foundation Vents

Ground-level venting, ground-level risk.

Foundation vents sit low on the home, moving air through the crawlspace, cellar, or basement to keep moisture from building up underneath. That same low position puts them in the path of wind-blown embers, which travel well ahead of a fire front and can ignite a home from the inside out through an unprotected opening.

wildland urban interface badge
astm e-84 class a rated icon
astm e-2768 ignition resistant rated icon
astm e-2886 ember flame diffuse listed icon

Multiple Flange Options

Every vent opening is a gap in the home’s fire defense.

Wildfire Tested & Code Compliant

Class A siding, stucco, and other fire-resistant cladding protect a home’s exterior surfaces well — but every unprotected vent opening is still a gap in that protection, and the foundation is no exception. V2 Vents close that gap with a stainless steel ember mesh that blocks embers on contact, no activation or reset required, while the V2 Matrix’s intumescent layer stands as a second line of defense against radiant heat and direct flame, expanding to seal the opening when it matters most.

*Some foundation, eave, and soffit models cross-apply between categories — the same vent body fits more than one installation context.

Built for Any Wall Material

Flange styles available:

  • Stucco Flange
  • Stucco Milcore
  • Foam Back Flange
  • Fiber Cement Flange
  • Flange Front
  • Plater Ground Flange
  • *Custom Flange*

Foundation / Crawlspace Applications: Flange Styles

V2-FSVFS-FF-install

Flange Front Foundation Vents

V2-FSVFS-S-install

Stucco Foundation Vent

V2-FSVFS-FB-install

Foam Back Foundation Vent

V2-FSVFS-FC-install

Fiber Cement Foundation Vent

* These diagrams are conceptual, not installation instructions — consult a licensed building professional for project-specific guidance.

Critical Step

Sealing the Install with EverKem

  • Use EverKem 814+ intumescent fire caulking on every V2 Vents installation. Round eave vents use EverKem 136 mortar-based caulking instead, where mounting hardware isn’t practical and flanges run minimal.
  • Installation: Run a bead of EverKem behind the nailing flange before setting the vent — this keeps the seam between vent and building material airtight, closing off any gap embers could use to get in.
Contact Us For Ordering

Close the Gap at the Foundation

Have a question about V2 Vents, wildfire-resistant construction, retrofit work, custom sizes, or a code-aware project? Get in touch and take the next step towards wildfire safety today.

wildfire mitigation contractor pointing at eave underside vents
foundation-open-face-graphic

No Baffles.
More Airflow.

Skipping the baffle lets air circulate more freely under the floor, especially in summer — good circulation is what keeps condensation from turning into mildew, mold, and rot underneath the house.

Without an airflow-restricting baffle, each vent delivers more net free area per square inch.

California’s Chapter 7A / CWUIC Chapter 5 Wildland-Urban Interface (WUI) code requires ember- and fire-resistant vents in high-risk fire zones — V2 Vents are built toward that standard, as recommended by the California State Fire Marshal (OSFM).

* Available for both new construction and as retrofit kits over existing openings.

Quality Manufacturing

What’s Built Into Every V2 Vent

V2 Matrix Intumescent Technology

Reacts at critical temperatures to defense against heat and flames

Exceptional Airflow

Our Net-Free-Vent-Area (NFVA) specifications are verified by accredited 3rd parties for airflow performance you can trust!

Code-Aware Design

Built to align with Wildland Urban Interface code in California’s Chapter 5 (Chapter 7A) -> CWUI and beyond -> IWUI etc.

Independently Tested

Evaluated to ASTM E2886 and ASTM2912 for resistance to ember entry and direct flame impingement in both, horizontal and vertical directions.

Foundation V2 Vents Spec Table

Protect the Part of the Home You Don’t See

* Within 5 miles of the coast, copper, stainless steel, or a powder-coated finish holds up better than standard galvanized against salt air. *

Foundation-Soffit V2 Vent

Filter by Flange Style
MFG. PART # DESCRIPTION Flange Style NFVA (sq. in.) Cut Out (in.) SPEC SHEET
FSVFS1824AV 18" x 24" FOUNDATION ACCESS VENT Flange Front 177 17.5 x 23.5 PDF
FSVFS414FB 4" x 14" FOAM BACK FLANGE SET BACK 1-1/2" Foam Back 24 3.5 X 13.5 PDF
FSVFS414FC 4" x 14" FIBER CEMENT FLANGE SET BACK 3/8" Fiber Cement 24 3.5 X 13.5 PDF
FSVFS414FF 4" x 14" FLANGE FRONT Flange Front 24 3.5 X 13.5 PDF
FSVFS414S 4" x 14" STUCCO SET BACK 3/4" Stucco 24 3.5 X 13.5 PDF
FSVFS614FB 6" x 14" FOAM BACK FLANGE SET BACK 1-1/2" Foam Back 41 5.5 X 13.5 PDF
FSVFS614FC 6" x 14" FIBER CEMENT FLANGE SET BACK 3/8" Fiber Cement 41 5.5 X 13.5 PDF
FSVFS614LFF 6" x 14" FLANGE FRONT Flange Front 20 6 X 14 PDF
FSVFS614FF 6" x 14" FLANGE FRONT Flange Front 41 5.5 X 13.5 PDF
FSVFS614S 6" x 14" STUCCO SET BACK 3/4" Stucco 41 5.5 X 13.5 PDF
FSVFS814FB 8" x 14" FOAM BACK FLANGE SET BACK 1-1/2" Foam Back 62 7.5 X 13.5 PDF
FSVFS814FC 8" x 14" FIBER CEMENT FLANGE SET BACK 3/8" Fiber Cement 62 7.5 X 13.5 PDF
FSVFS814FF 8" x 14" FLANGE FRONT Flange Front 62 7.5 X 13.5 PDF
FSVFS814LFF 8" x 14" FLANGE FRONT Flange Front 31 8 X 14 PDF
FSVFS814S 8" x 14" STUCCO SET BACK 3/4" Stucco 62 7.5 X 13.5 PDF

Let’s Build a Safer Future!

Give us a call or submit your information via the form and a team member will get back to you.

phone icon

Phone

(916) 652-7424

clock icon

Hours

Mon. – Fri. 8AM – 4PM Pacific Time

email icon

Email

info@firestormbp.com

Early Product Launch Announcement!

We are making FireStorm Building Products available to the public early due to the overwhelming demand!

You can access our products in one of two ways:

California Residents

Please enter your zip code to find a store near you!

Non-California Residents

Please contact us for a free quote!

Contact Us