Louvered Vents

Attic Protection

Louvered vents shed wind-driven rain, snow, and critters while still moving air — most often at gable-end walls feeding an attic, or low on the home at foundation and crawlspace openings. In summer, rising heat gets trapped under the roof even with air conditioning running, so high-wall venting matters for releasing it and keeping attic temperatures stable. Winter brings the same problem in reverse, with wider swings stressing an unvented attic. Lower on the wall, that same airflow keeps foundation and crawlspace air from turning damp and stale — the conditions that breed mold, mildew, and musty odors.

wildland urban interface badge
astm e-84 class a rated icon
astm e-2768 ignition resistant rated icon
astm e-2886 ember flame diffuse listed icon

Product Lineup

Open for everyday airflow. Sealed shut when it counts.

V2 Vents’ continuous soffit louvers run the full length of the soffit, delivering consistent ventilation into the attic space along the entire run.

Suited to new construction across multiple materials, with retrofit kits available for existing continuous vents. Skipping the airflow-restricting baffle found in some designs means more net free area per square inch, and a stainless steel ember screen paired with an intumescent matrix seals the vent shut under high heat.

Flange Styles for Louver Applications

These installation examples show how different flange styles layer into a wall opening for new or existing construction. Because louvered vents are durable and weather-resistant, they also work well as foundation/crawlspace vents.

V2-FSVG-FF-install

Flange Front Louvered Vent

V2-FSVG-S-install

Stucco Louvered Vent

V2-FSVG-FB-install

Foam Back Louvered Vent

V2-FSVG-FC-install

Fiber Cement Louvered Vent

Critical Step

Sealing the Install with EverKem

  • Use EverKem 814+ intumescent fire caulking on every V2 Vents installation. Round eave vents use EverKem 136 mortar-based caulking instead, where mounting hardware isn’t practical and flanges run minimal.
  • Installation: Run a bead of EverKem behind the nailing flange before setting the vent — this keeps the seam between vent and building material airtight, closing off any gap embers could use to get in.
Contact Us For Ordering

Code Compliant Ventilation

Where the Attic Meets the Fire

Attics and crawlspaces are already among the most exposed parts of a home during a wildfire — and any space that needs ventilation is, by definition, a space with an opening to protect. V2 Vents pairs a stainless steel ember-stopping mesh with an intumescent honeycomb layer that expands to block heat and flame, while still letting the attic, foundation, or crawlspace breathe normally day to day.

v2 vent mesh

A Louver That Still Performs Under Fire

Have a question about V2 Vents, wildfire-resistant construction, retrofit work, custom sizes, or a code-aware project? Get in touch and take the next step towards wildfire safety today.

balcony-inspection-vents-twins

Layered Protection

The Protection Is Behind the Louver, Not In Front of It

An ember-catching mesh screen and heat-reactive intumescent coating do the protective work here — positioned behind the louver face, so the vent reads as a standard louvered opening while carrying wildfire-rated performance underneath.

Building Materials

Installs Into the Construction You Already Have

Class A siding, stucco, and other fire-resistant cladding protect a home’s exterior surfaces well — but every unprotected vent opening is still a gap in that protection. V2 Vents close that gap with a stainless steel ember mesh that blocks embers on contact, no activation or reset required, while the V2 Matrix’s intumescent layer stands as a second line of defense against radiant heat and direct flame, expanding to seal the opening when it matters most.

Built for Any Materials

  • Wood Siding
  • Stucco
  • Mil Core
  • Foam Back
  • Fiber Cement

Retrofit V2 Vents

Choosing a Retrofit Flange

Not every flange style suits a retrofit.

Flange styles designed to sit behind exterior cladding are hard to use once shingles or stucco are already in place. If removing the existing vent is an option, a Flange Front (FF) style is the usual choice.

‘Retrofitting’ and ‘home hardening’ both describe upgrading or replacing an existing vent with a fire- and ember-resistant one. V2 Vents offers a retrofit-flange louvered vent designed to install directly over an existing louvered vent face — though it isn’t the only option.

For more flexibility, the V2 Matrix is available as a standalone product — cut to fit and install from the back side of an existing vent opening. It works across louvered vents, dormers, and foundation vents alike.

v2-retrofit-vent

Quality Manufacturing

What’s Built Into Every V2 Vent

V2 Matrix Intumescent Technology

Reacts at critical temperatures to defense against heat and flames

Exceptional Airflow

Our Net-Free-Vent-Area (NFVA) specifications are verified by accredited 3rd parties for airflow performance you can trust!

Code-Aware Design

Built to align with Wildland Urban Interface code in California’s Chapter 5 (Chapter 7A) -> CWUI and beyond -> IWUI etc.

Independently Tested

Evaluated to ASTM E2886 and ASTM2912 for resistance to ember entry and direct flame impingement in both, horizontal and vertical directions.

Foundation V2 Vents Spec Table

Protect the Part of the Home You Don’t See

* Within 5 miles of the coast, copper, stainless steel, or a powder-coated finish holds up better than standard galvanized against salt air. *

Louvered V2 Vent

Filter by Flange Style
MFG. PART # DESCRIPTION Flange Style NFVA (sq. in.) Cut Out (in.) SPEC SHEET
FSVG148FB 14" x 8" FOAM BACK FLANGE recessed 1-1/2" Retrofit - V2 Matrix Dependant N/A PDF
FSVG148FC 14" x 8" FIBER CEMENT FLANGE recessed 3/8" Retrofit - V2 Matrix Dependant N/A PDF
FSVG148FF 14" x 8" FLANGE FRONT Retrofit - V2 Matrix Dependant N/A PDF
FSVG148FM 14" x 8" FLANGE MIDDLE recessed 1-5/16" Flange Front 24 4.75 X 12.75 PDF
FSVG148R 14" x 8" RETROFIT FLANGE recessed 2-5/8" Flange Front 58 14 X 12 PDF
FSVG148S 14" x 8" FLANGE SET BACK 3/4" STUCCO Recessed 58 14 X 12 PDF
FSVG1412FB 14" x 12" FOAM BACK FLANGE recessed 1-1/2" Retrofit 58 14 X 12 PDF
FSVG1412FC 14" x 12" FIBER CEMENT FLANGE recessed 3/8" Stucco 58 14 X 12 PDF
FSVG1412FF 14" x 12" FLANGE FRONT Foam Back 86 14 X 17.5 PDF
FSVG1412FM 14" x 12" FLANGE MIDDLE recessed 1-5/16" Fiber Cement 86 14 X 17.5 PDF
FSVG1412R 14" x 12" RETROFIT FLANGE recessed 2-5/8" Flange Front 86 14 X 17.5 PDF
FSVG1412S 14" x 12" FLANGE SET BACK 3/4" STUCCO Recessed 86 14 X 17.5 PDF
FSVG1418FB 14" x 18" FOAM BACK FLANGE recessed 1-1/2" Retrofit 86 14 X 17.5 PDF
FSVG1418FC 14" x 18" FIBER CEMENT FLANGE recessed 3/8" Fiber Cement 115 14 X 23.5 PDF
FSVG1418FF 14" x 18" FLANGE FRONT Flange Front 115 14 X 23.5 PDF
FSVG1418FM 14" x 18" FLANGE MIDDLE recessed 1-5/16" Recessed 115 14 X 23.5 PDF
FSVG1418R 14" x 18" RETROFIT FLANGE recessed 2-5/8" Retrofit 115 14 X 23.5 PDF
FSVG1418S 14" x 18" FLANGE SET BACK 3/4" STUCCO Stucco 115 14 X 23.5 PDF
FSVG1424FB 14" x 24" FOAM BACK FLANGE recessed 1-1/2" Fiber Cement 29 14 X 7.5 PDF
FSVG1424FC 14" x 24" FIBER CEMENT FLANGE recessed 3/8" Flange Front 29 14 X 7.5 PDF
FSVG1424FF 14" x 24" FLANGE FRONT Recessed 29 14 X 7.5 PDF
FSVG1424FM 14" x 24" FLANGE MIDDLE recessed 1-5/16" Retrofit 29 14 X 7.5 PDF
FSVG1424R 14" x 24" RETROFIT FLANGE recessed 2-5/8" Stucco 29 14 X 7.5 PDF
FSVG1424S 14" x 24" FLANGE SET BACK 3/4" STUCCO Foam Back 58 14 X 12 PDF
FSVG4.75X12.75FF 4-3/4" X 12-3/4" FLANGE FRONT Stucco 86 14 X 17.5 PDF
FSVM1424 14" x 24" NFVA DEPENDANT ON OPENINGS Foam Back 115 14 X 23.5 PDF
FSVM2424 24" x 24" NFVA DEPENDANT ON OPENINGS Fiber Cement 58 14 X 12 PDF
FSVM4824 48" x 24" NFVA DEPENDANT ON OPENINGS Foam Back 29 14 X 7.5 PDF

Let’s Build a Safer Future!

Give us a call or submit your information via the form and a team member will get back to you.

phone icon

Phone

(916) 652-7424

clock icon

Hours

Mon. – Fri. 8AM – 4PM Pacific Time

email icon

Email

info@firestormbp.com

Early Product Launch Announcement!

We are making FireStorm Building Products available to the public early due to the overwhelming demand!

You can access our products in one of two ways:

California Residents

Please enter your zip code to find a store near you!

Non-California Residents

Please contact us for a free quote!

Contact Us